Panasonic DMC-F5EB 서비스 매뉴얼 - 페이지 4
{카테고리_이름} Panasonic DMC-F5EB에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Panasonic DMC-F5EB 27 페이지.
1.4.
How to Discharge the E.Capacitor on the Flash Unit
CAUTION:
1. Make sure to discharge the E.capacitor on the Flash Unit.
2. Be careful of the high voltage circuit on the Flash Unit when servicing.
[Discharging Procedure]
1. Refer to the disassemble procedure and remove the necessary parts/unit.
2. Install the insulation tube onto the lead part of resistor (ERG5SJ102:1kΩ /5W).
(an equivalent type of resistor may be used.)
3. Place a resistor between both terminals of E.capacitor on the Flash Unit for approx. 5 seconds.
4. After discharging, confirm that the E.capacitor voltage is lower than 10V using a voltmeter.
Fig. F1
4