TROUBLESHOOTING
Problem
WATER PUMP
NOT WORKING
WATER PUMP
IS NOISY
PMAX EVOII 1910_2910_3910_4910 DC Pump Instructions.indd 10
Reason
No Power
Sponges and filter media blocked with
sludge.
Impellor is blocked with sludge or lime
scale build up.
Running without sufficient water.
Blocked Impellor chamber or
ceramic shaft is broken.
Blockage in pump.
Impellor & Shaft worn out.
Impellor broken.
Water valve closed on the inlet or outlet.
Unit inlet is blocked or the water pump
outlet is blocked.
The height to which you are pumping is too
high for the given model of pump.
A Q U A T E C E Q U I P M E N T . C O M
Solution
Check that the plug is connected and
power point turned on.
Clean the sponges and filters.
Clean the Impellor as per the instructions.
Submerse the equipment underwater
then plug in. Refill if necessary.
Clean the Impellor. Check for wear.
Replace if necessary.
Clear the blockage.
Replace Impellor & Shaft.
Replace Impellor.
Open the valve and allow.
Clear all blockages.
Select a bigger model.
22/12/16 7:33 am