Configuration procedures
Physically install and configure the disk array and the server as described below and in the manuals for
those products. Refer to the diagram under
Configuration summary
You will perform the following tasks during configuration:

VDS Provider Windows 2003 server:

Install Windows 2003 Server OS.
Install FC Host Bus Adapter and driver.
Connect the server HBA to the array using a FC switch and set up zoning (if required).
Install NIC card and connect to Ethernet LAN (optional).
Install HP MPIO software if multipathing is desired.

Disk array and host:

Connect the array to the VDS Server through the FC switch.
Verify existing or install MPIO software license.
Important configuration notes:
Administrator privileges are required for all devices and software. If you do not have administrator
privileges, the software and hardware will not communicate properly.
When using the VDS framework to create and manage LUNs, the LUNs should be the same size as the
physical disk size. You can make LUNs smaller than a physical disk (or disks, if spanning multiple disks),
but any space left over on the physical disk(s) cannot be used. For example, if you have three 36
GB drives totalling 108 GB and you create a LUN of 20 GB spanning all three disks, the remaining
88 GB are unusable.
You may use Basic MPIO with the disk array and Provider server, but you will not be able to use VDS to
manage MPIO. Use whatever MPIO configuration software you have available to manage MPIO.
20
Configuration
Components
for an overview of interconnections.