HP 353803-B22 - StorageWorks Modular Smart Array 1000 SAN Starter 관리 매뉴얼 - 페이지 21

{카테고리_이름} HP 353803-B22 - StorageWorks Modular Smart Array 1000 SAN Starter에 대한 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. HP 353803-B22 - StorageWorks Modular Smart Array 1000 SAN Starter 40 페이지. Storageworks modular smart array controller, cache, and battery replacement instructions
HP 353803-B22 - StorageWorks Modular Smart Array 1000 SAN Starter에 대해서도 마찬가지입니다: 참조 매뉴얼 (48 페이지), 릴리스 노트 (13 페이지), 빠른 시작 지침 (8 페이지), 릴리스 노트 (8 페이지), 릴리스 노트 (8 페이지), 빠른 시작 매뉴얼 (7 페이지), 릴리스 노트 (5 페이지), 교체 지침 (4 페이지)

HP 353803-B22 - StorageWorks Modular Smart Array 1000 SAN Starter 관리 매뉴얼
Configuring the HP Provider server
Install and configure the Windows 2003 server that will run the HP VDS Provider software as follows:
1.
If it is not already present, install the Windows 2003 Server OS on the server that will run the
HP Provider software.
2.
Install a Fibre Channel host bus adapter (HBA) card into the server according to the HBA
manufacturer's instructions.
3.
Install the HBA driver and utility software onto the server according to the HBA manufacturer's
instructions. HP tested drivers are available from HP Support. Follow the README file that comes
with the driver for installation.
4.
Connect the server to the disk array via the built-in Fibre Channel fabric switch, if present, or an
external switch. Configure the switch, including zoning if required, according to the manufacturer's
instructions. For helpful information on SAN construction, see the HP StorageWorks SAN Design
Reference Guide. To locate this guide, visit the HP Manuals web site listed in the front of this book
under
Related
5.
If desired, connect the server to the corporate Ethernet LAN (optional). A firewall is recommended
but optional. Be sure the firewall is open between the MSA host and the HP Provider server.
6.
Install MPIO software on the VDS Provider server according to the MPIO Installation Guide.
7.
Complete the rest of configuration in this chapter and then install the required HP VDS Provider
software on the server as explained in "Chapter 3 Installation.
Configuring the disk array and optional host
Ensure the disk array has been fully installed and configured. Install the Array Configuration Utility
software on the optional host, if desired. For details, refer to the HP Array Configuration Utility User
Guide. Make sure the license for the MPIO software, if used, is installed according to the MPIO Installation
Guide. Ensure the array is connected through a FC switch to the Provider server as explained previously.
NOTE:
When using the VDS framework to create and manage LUNs, the LUNs should be the same size as the
physical disk size. You can make LUNs smaller than a physical disk (or disks, if spanning multiple disks),
but any space left over on the physical disk(s) cannot be used. For example, if you have three 36
GB drives totalling 108 GB and you create a LUN of 20 GB spanning all three disks, the remaining
88 GB are unusable.
documentation. Search for the link to "HP StorageWorks SAN."
HP Modular Smart Array FC VDS Hardware Provider administration guide
21