HP StorageWorks 2/32 - SAN Switch 릴리스 노트 - 페이지 32
{카테고리_이름} HP StorageWorks 2/32 - SAN Switch에 대한 릴리스 노트을 온라인으로 검색하거나 PDF를 다운로드하세요. HP StorageWorks 2/32 - SAN Switch 32 페이지. Fabric manager version 3.0.x release notes
HP StorageWorks 2/32 - SAN Switch에 대해서도 마찬가지입니다: 설치 지침 매뉴얼 (20 페이지), 사용자 설명서 (22 페이지), 펌웨어 릴리스 노트 (14 페이지), 릴리스 노트 (48 페이지), 설치 지침 매뉴얼 (6 페이지), 릴리스 노트 (14 페이지), 릴리스 노트 (4 페이지)

Known Issues
Web Tools and Firmware Download
Firmware download and activation involves multiple phases. When Web Tools reports
that firmware download has completed successfully, this indicates that a basic sanity
check, package retrieval, package unloading and verification was successful.
NOTE: Web Tools currently forces a full package install. To perform an incremental upgrade,
use the CLI.
A reboot is required to activate the newly downloaded firmware. The reboot is done
automatically from the Web Tools user perspective, and results in a loss of network
connectivity with Web Tools. Web Tools screens continue to be visible during the
reboot, but will not be available. Wait approximately 10 minutes to ensure all
application windows are restored. If Web Tools fails to respond after 20 minutes, you
may need to close all Web Tools applications windows and restart them, or contact the
system administrator for network assistance. The SAN Switch 2/32 loss of network
connectivity due to reboot is approximately 4 minutes if diagpost is disabled and 8
minutes if diagpost is enabled.
Troubleshooting the I2C Time-out message
If an "
EM, I2C_TIMEOUT
fault (usually transient) or there is a hardware problem.
Recommended Steps
Use these steps to determine if there is a hardware problem.
1. Determine which component is indicated. The message provides the information
as follows:
<fru_type> <unit> I2C timed out: state <curr_state>
2. Check the LEDs on the related hardware component.
3. Enter the switchstatusshow, chassisshow, and sensorshow
commands.
4. Take the appropriate action:
NOTE: If the LEDs and command printouts indicate that all components are healthy, then it was
a transient I2C bus fault, and no action is required.
If one of the components appears to be faulted, try reseating the component. If it still
appears to be faulty, replace the component.
32
" message displays, then either the I2C bus experienced a
SAN switch 2/32, version 4.0.2b release notes