Table 8
Fabric OS 4.4.0d closed issues summary
Closed defect
Issue: swFCPortLinkState is
not in sync with
portdisable/portenable on
FOS4.4.x.
Symptom: Pre-FOS 4.4.0, the status
of SW-MIB::swFCPortLinkState
changed according to portEnable
and portDisable commands. In FOS
4.4.0x, unless the FC cable is
connected to the switch, it always
shows the port as disabled.
Issue: When using FOS 4.4.x as a
proxy to manage a future new
platform with greater then 128
ports, any MS command (except
Vendor Unique New Generation
commands) may fail if the receiving
data exceeds 3K limit.
Symptom: When FOS 4.4.0x
switch is used as proxy, API
GetObjectsByType is returning
an error code -221.
Status
Fixed
Fixed
Fabric OS 4.4.0f release notes