HP StorageWorks 2/8V - SAN Switch 설치 지침 매뉴얼
Item
Description
Eight #10 adapter washers
Two 1/4-20 hex nuts with
captive star lock washers
Two 1/4-inch flat washers
CAUTION:
For proper airflow, the SFP+ media side of the device port side
must face the rear of the rack. This allows cool air to enter the
front of the rack and exit from the rear.
To install the device in a rack:
1.
Verify that the required parts and hardware are available. (See
Table
1.)
2.
Choose a mounting location for the device in the rack.
3.
Attach the rear mounting brackets to the rear rack uprights.
• For an HP 10000 Series Rack, assemble each of the brackets
using two #10-32 x 1/2-inch Phillips panhead screws with
captive star lock washers and two #10 adapter washers, as
shown in
Figure
• For an HP System/e Rack, install the two rear mounting brackets
with two #10-32 x 1/2-inch Phillips panhead screws and two
#10 alignment washers, as shown in
Figure 1 Installing the rear mounting brackets (HP 10000 Series
Rack)
Figure 2 Installing the rear mounting brackets (HP System/e Rack)
NOTE:
The SAN Switch Rack Mount Kit contains rails labeled
Left and Right to designate the left side and right side
of the device or cabinet as viewed from the front of the
cabinet.
Page 3
1.
Figure
2.