Aquatek ATCBF Series 운영 및 유지보수 매뉴얼 - 페이지 10

{카테고리_이름} Aquatek ATCBF Series에 대한 운영 및 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aquatek ATCBF Series 19 페이지. Arsenic systems

Installation CONT.
6. Locate Polytube Insert: Now that the water softener is connected to the existing plumbing, the drain
line may be connected. First, locate and remove the polytube insert (#2) from the gray cable on the
left side of the control valve. (See Figure 4)
7. Connecting the Drain Line: Slide plastic nut (#3) over the permanent drain tubing and place the
polytube insert (#2) into the end of the drain tubing. Insert the drain tubing into the drain elbow fitting
(#4) and tighten plastic nut (#3) hand-tight plus 1/2 turn with pliers. Caution: Do Not Over-tighten.
(See Figure 4)
8. Drain Line Specs: If the distance from the water filter to the drain is greater than 20' the drain line
size must be increased to 3/4". The threads on the drain elbow fitting are 3/4" male NPT and can be
used in lieu of the 1/2" plastic nut and insert. If the drain line must run overhead, the maximum height
of the drain line should not exceed 8' above the top of the water softener.
9. Air Gap: The drain line must have an approved air gap to prevent the possibility of a cross connec-
tion to the sewer. (See Figure 5)
10. IMPORTANT: Special precautions must be made when connecting the drainline. During backwash,
high volumes of air and water escape rapidly, causing a flexible drain line to whip and thrash. Rigid
drain piping is highly recommended.
***Disclaimer*** United Water strongly recommends that each system be installed by a
licensed and knowledgeable professional. Failure to do so could result in property dam-
All systems MUST be installed in accordance with local and state plumbing codes.
Fig. 1
Fig. 2 (optional)
10
age, equipment failure and potentially void warranty.
Fig. 3
UNITED WATER INC.
A
AtCBF-AS-S
quAtek
Fig. 4
Fig. 5
u
G
erieS
Ser
uide