Aquatek ATCBF Series 운영 및 유지보수 매뉴얼 - 페이지 17

{카테고리_이름} Aquatek ATCBF Series에 대한 운영 및 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aquatek ATCBF Series 19 페이지. Arsenic systems

Problem
Timer does not display
time of day
The Timer does not dis-
play the correct time of
day
Control valve back-
washes at the wrong
time of day
The unit is leaking
Reduced water flow or
pressure
Control valve stalled in
the backwash
Control valve does not
automatically back-
wash when REGEN
button is depressed
and held
Control valve does not
automatically back-
wash but does when
REGEN button is de-
pressed and held

Trouble Shooting Guide

Possible Cause
Transformer unplugged
No electrical power at the outlet
Defective Transformer
Defective PC board
Switched outlet
Power outage
Defective PC board
Time of day is not set correctly
Time of backwash is set incorrectly
Power outage
Fittings are loose
The tank is cracked
Damaged drain line or hose
Breakdown of the media
Media has begun to solidify
Overload of sediment or clogging of
media
Motor not operating
No electrical power at outlet
Defective transformer
Defective PC board
Broken piston retainer
Broken main or regenerant piston
Broken drive gear or drive cap assem-
bly
Transformer unplugged
No electrical power at outlet
Broken drive gear or drive cap assem-
bly
Defective PC board
Defective PC board
Set-up error
UNITED WATER INC.
A
AtCBF-AS-S
quAtek
Solution
Connect power
Repair outlet or use working outlet
Replace transformer
Replace PC Board
Use uninterrupted outlet
Reset time of day
Replace PC board
Reset to correct time of day
Reset backwash time
Reset valve to correct time of day
Tighten fittings
Bypass unit (See pg. 13)
Replace drain line or hose
Bypass unit (See pg. 13) and replace
the media. Contact us to replace me-
dia - 877-414-PURE
Replace motor
Repair or use working outlet
Replace transformer
Replace PC board
Replace drive cap assembly
Replace main or regenerant piston
Replace drive gear or drive cap as-
sembly
Connect transformer
Repair or use working outlet
Replace drive gear or drive cap as-
sembly
Replace PC board
Replace PC board
Check control valve set-up procedure
u
G
erieS
Ser
uide
17