HP StorageWorks 8/40 - SAN Switch 릴리스 노트 - 페이지 15

{카테고리_이름} HP StorageWorks 8/40 - SAN Switch에 대한 릴리스 노트을 온라인으로 검색하거나 PDF를 다운로드하세요. HP StorageWorks 8/40 - SAN Switch 43 페이지. Hp storageworks fabric os 6.1.2b release notes (5697-0351, march 2010)
HP StorageWorks 8/40 - SAN Switch에 대해서도 마찬가지입니다: 릴리스 노트 (30 페이지), 릴리스 노트 (29 페이지), 릴리스 노트 (32 페이지)

HP StorageWorks 8/40 - SAN Switch 릴리스 노트
Power supply requirements for Director blades
Table 4
lists power supply requirements for Director blades to provide full redundancy (220 VAC
power is assumed).
IMPORTANT:
Director blades must meet minimum Fabric OS levels to operate in the Director chassis. For example,
the FC8-32 is not supported in the 4/256 SAN Director with Fabric OS 6.0.x.
Table 4 Power supplies required for blades in Director chassis
Director blade
FC4-16
FC4-32
FC4-48
FC8-16
FC8-32
FC8-48
FC10-6
FR4-18i (FCIP/FC Router blade)
FC4-16IP (iSCSI blade)
FS8–18 (HP DC Switch Encryption
FC blade)
1
The DC Director can operate with nominal power of 110 VAC. See the appropriate hardware reference guide for power
specifications.
Fibre Channel Routing scalability
For the latest FCR scalability support information, see the HP StorageWorks SAN design reference
guide, available at:
http://www.hp.com/go/sandesignguide
4/256 SAN Director
Two power supplies
Four power supplies
Four power supplies
Not supported
HP StorageWorks Fabric OS 6.2.0b release notes
DC SAN Backbone Director and
1
DC04 SAN Director
Two power supplies
Two power supplies
Two power supplies. The FC4-16IP
blades are not supported in the DC
SAN Backbone and DC04
Directors.
Two power supplies. Requires 220
VAC in the DC04 SAN director.
15