HP StorageWorks 8B - FC Entry Switch 매뉴얼
4
Displaying Error Logs and Status
This command also display the following information for ports on the specified switch:
For more information refer to the switchShow command in the Fabric OS Reference Manual.

Displaying the Uptime Of The Switch

To display the uptime for a switch:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
uptime
This command displays the length of time the system has been in operation, the total
cumulative amount of "up time" since the system was first powered-on, the date and time of
the last reboot, and the reason for the last reboot.
The reason for the last switch reboot is also recorded in the error log.

Displaying the Fan Status

To display the fan status of a switch:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
fanShow
The possible values for fan status are:
OK - Fan is functioning correctly.
absent - Fan is not present.
below minimum - Fan is present but rotating too slowly or stopped.
4-4
switchRole - The switch's role: Principal, Subordinate, or Disabled.
switchDomain - The switch's Domain ID.
switchId - The switch's embedded port D_ID.
switchWwn - The switch's World Wide Name.
switchBeacon - The switch's beaconing state: either ON or OFF.
Module type - The SFP type if an SFP is present.
Port speed - The speed of the Port (1G, 2G, N1, N2, or AN). The speed can be fixed,
negotiated, or auto negotiated.
Port state - The port status.
Comment - Displays information about the port. May be blank or including WWN for
F_port or E_port, Trunking state, upstream or downstream status.
Fabric OS Procedures Guide