HP StorageWorks 8B - FC Entry Switch 사용자 설명서 - 페이지 23

{카테고리_이름} HP StorageWorks 8B - FC Entry Switch에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. HP StorageWorks 8B - FC Entry Switch 44 페이지. Fabric os release notes version 3.0.1b
HP StorageWorks 8B - FC Entry Switch에 대해서도 마찬가지입니다: 업데이트 매뉴얼 (9 페이지), 설치 지침 매뉴얼 (20 페이지), 사용자 설명서 (22 페이지), 펌웨어 릴리스 노트 (14 페이지), 설치 매뉴얼 (14 페이지), 릴리스 노트 (26 페이지), 매뉴얼 (50 페이지), 사용자 설명서 (44 페이지), 사용자 설명서 (38 페이지), 사용자 설명서 (38 페이지), 사용자 설명서 (37 페이지), 사용자 설명서 (30 페이지), 릴리스 노트 (16 페이지)

HP StorageWorks 8B - FC Entry Switch 사용자 설명서

End-to-end Performance Monitoring

End-to-end performance monitoring counts the number of words and CRC errors in Fibre Channel
frames for a specified Source ID (SID) and Destination ID (DID) pair. An end-to-end performance
monitor counts:
To enable end-to-end performance monitoring, you must configure an end-to-end monitor on a
port, specifying the SID-DID pair. The monitor counts only those frames with matching SID and
DID.
Each SID or DID has three fields, listed in the following order:
For example, the SID 0x118a0f has Domain ID 0x11, Area ID 0x8a, and AL_PA 0x0f. (The prefix
"0x" denotes a hexadecimal number.)

Adding End-to-end Monitors

Use the perfAddEEMonitor command to add an end-to-end monitor to a port. With this command
you specify the port, the SID, and the DID that you want to monitor. Depending on the application,
you can select any port along the routing path for monitoring.
Example.
Dev B, which is connected to port 15 on switch 2.
Figure 3-1
To monitor the traffic from Host A to Dev B, add a monitor to port 2, specifying 0x051200 as the
SID and 0x111eef as the DID. To monitor the traffic from Dev B to Host A, add a monitor to port
15, specifying 0x111eef as the SID and 0x051200 as the DID. Use the following commands:
sw1:admin> perfAddEEMonitor 2, "0x051200", "0x111eef"
End-to-End monitor number 0 added.
-----------------------------------------------------
sw2:admin> perfAddEEMonitor 15, "0x111eef", "0x051200"
End-to-End monitor number 1 added.
Advanced Performance Monitoring User's Guide
the number of words in frames received at the port (RX_COUNT)
the number of words in frames transmitted from the port (TX_COUNT)
the number of CRC errors in frames received at the port (CRC_COUNT)
Domain ID (DD)
Area ID (AA)
AL_PA (PP)
Figure 3-1
shows two devices: Host A, which is connected to port 2 on switch 1, and
SID
Switch 1
0x051200
Host
A
Monitor 0
on port 2
Setting end-to-end monitors on a port
Using Advanced Performance Monitoring
Switch 2
0x111eef
. . .
. . .
Monitor 1
on port 15
3
DID
Dev
B
3-3