HP surestore fc 1Gb entry switch 8B 매뉴얼 - 페이지 21

{카테고리_이름} HP surestore fc 1Gb entry switch 8B에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. HP surestore fc 1Gb entry switch 8B 50 페이지. Fabric os procedures guide (version 3.0)

4.
Verify the threshold settings you have configured for each parameter. Enter the following
command to view your current switch status policy configuration:
switchStatusPolicyShow
Note:

Enabling the Track Changes Feature

To enable the track changes feature:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
trackChangesSet 1
A prompt is displayed verifying that the track changes feature is on. The output from the track
changes feature is dumped to the error log for the switch. Use the errdump command or
errshow command to view the error log.
Trackable changes are:
Items in the error log created from the Track changes feature are labeled Error TRACK. For
example:
Error 08
--------
0x102cf710 (tShell): May
Fabric OS Procedures Guide
Enter the number of port down warnings required to change the switch status to DOWN
and press the Enter key.
Enter the number of port down warnings required to change the switch status to
MARGINAL and press the Enter key.
Enter the number of ISLstatus down warnings required to change the switch status to
DOWN and press the Enter key.
Enter the number of ISLstatus down warnings required to change the switch status to
MARGINAL and press the Enter key.
By setting the DOWN and MARGINAL value for a parameter to 0,0 that parameter is
ignored in setting the overall status for the switch.
Successful login
Unsuccessful login
Logout
Config file change from task
Track-changes on
Track-changes off
Error TRACK-LOGIN, 4, Successful login
Basic Configuration Procedures
2 16:12:10
2
2-7