Forcing In-order Delivery of Frames
To force in-order delivery of frames during fabric topology changes:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
iodset
Note:
Disabling In-order Delivery of Frames
To disable In-Order Delivery of frames during fabric topology changes:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
iodreset
Displaying Help Information for a Telnet Command
To display help information about a telnet command:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
help command
where command is the command name you would like help with.
Fabric OS Procedures Guide
This command can cause a delay in the establishment of a new path when a topology
change occurs, and should be used with care.
Basic Configuration Procedures
2
2-9