Diamond Needle White Diamond CG-750AJ 매뉴얼 - 페이지 4
{카테고리_이름} Diamond Needle White Diamond CG-750AJ에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Diamond Needle White Diamond CG-750AJ 4 페이지.
2. when power failure occurs check the power cord, trigger switch and motor.
3. When the spray dispersion is forked, it means the nozzle is blocked or
clogged. Take off the nozzle and remove debris using a thin sharp, needle-like
tool.
4. When pump cylinder jamming occurs, no liquid will be sprayed out. If the
motor rumbles, replace the entire pump cylinder.
5. When the spray gun is buzzing and only some liquid spurts out, it usually is
a failure of the motor coil. Change the motor.
6. When the spray pattern is not continuous and the flow reduces to 1/3 of
normal output, it is the failure of the cylinder spring. Change the cylinder
spring.
Notes
Use only specified rated voltage and cycles.
Must be properly grounded to avoid electric shock.
Always keep the top side up when in use.
Do not spray onto any part of human or animal body.
Do not use in a wet environment.
Do not spray onto flammable objects.
Keep out of reach of children.
Keep the spray gun in a safe place.
Do not substitute any components except with those of the original
manufacturer.
4