PLUMBING & WATER CONNECTIONS
6. POOL/SPA COMBINATIONS W/SPILL-OVER
Use this diagram for a connected pool and spa, where the spa has a spill-over type waterfall into
HEAT PUMP
the pool. Where
one pump and
one heater are
used for both
t h e p o o l a n d
spa. If the water
pump exceeds
1.5 H.P. then in-
stall a external
bypass as shown
on page 5.
SPA JETS
SEE CHLORINATOR LOOP & CHECK
VALVE REQUIREMENT ON PAGE 5.
JANDY™
3-WAY VALVE
HEAT PUMP
IN
OUT
6a.POOL & SPA SEPERATE
Use this diagram for a separate pool
and spa not connected, and does not
have a spill-over. Where the pool and
the spa have separate pump & filter
systems but using the same heater. If
the water pump exceeds 1.5 H.P. then
install a external bypass as shown on
page 5.
Titanium Instal Manuals.indd 6
WATER
FILTER
PUMP
Jandy™
3-Way Valve
VERTICAL
CHLORINATOR
LOOP
POOL
SPA
SPA
POOL
TO
FROM
TO SPA
SPA
SPILLOVER
SUCTION
CHLORINATOR
TO POOL
RETURN
FROM
POOL
SKIMMER�
SUCTION
POOL
FILTER
VERTICAL
CHLORINATOR
LOOP
BYPASS
12 LB
POOL
CHECK
CHLORINATOR
VALVE
FROM
FROM
POOL
POOL
VERTICAL
FLOOR
SKIMMER
CHLORINATOR
SUCTION
SUCTION
LOOP
TO POOL
RETURNS
BYPASS
12 LB
CHECK
VALVE
SPA
TO SPA
CHLORINATOR
RETURN JETS
SPA
FILTER
WATER PUMP
FROM
SPA
SUCTION
-6-
ELECTRICAL CONNECTIONS AND WIRING
OPTIONAL REMOTE KEYPAD WIRING DIAGRAM
for "Digital Logic" Digital Control Models with Time Clock Override Option Only
REMOTE KEY PAD
(REAR)
4 WIRE #18 A.W.G.
INSULATED CABLE
FROM
POOL�
FLOOR
SUCTION
POOL
WATER
PUMP
TERMINAL-TB4 FOR REMOTE KEY PAD
4. MOTORIZED ACTUATOR CONNECTION FOR POOL/SPA
COMBINATION
MAKE SURE TO TURN OFF ALL POWER TO UNIT INCLUDING
POWER TO POOL PUMP TIMER PRIOR TO MAKING ANY ELEC-
• Install motorized actuators on proper valves in pool/spa plumbing. (see plumb-
ing diagrams).
• Feed actuator wires through knockout in base of low voltage electric compart-
ment.
• Plug in actuator wire lead to motor valve sockets located on the right side of
the circuit board in unit. Make sure to plug in suction and return actuator wires
to appropriate socket.
• Run the actuator wires through the slot provided on the right side of the unitʼs
plastic front cover.
• Turn power to unit and timeclock on.
SPA
BROWN
4 POSITION
"REMOVABLE"
TERMINAL
#1 RED
#2 BLK
#3 YEL
EXISTING KEY PAD
#4 GRN
WITH T.C.O. OPTION
FAN
240 VAC
P
COM.
BROWN 4 POSITION "REMOVABLE"
TRICAL CONNECTIONS.
-11-
SUCTION
RETURN
S
JANDY MOTOR
VALVE SOCKETS
11/19/04 4:05:58 PM