acceptable for use in surface and subsurface irrigation, including irrigation of edible crops without
the edible portion being in direct contact with the treated water. A reuse tank may be required if the
irrigation system requires it. The holding tank and plumbing system for reuse water shall meet all
applicable codes; have proper backflow prevention and protection against cross connections; and is
the responsibility of the local designer/installer. Additional disinfection should be considered to
provide adequate disinfection to prevent microorganism growth in the treated reuse water storage
EVALUATION OF SYSTEM
PERFORMANCE
A general evaluation of a BioBarrier
performance can be made using some simple
observations which are outlined in the "Trouble Shooting"
guide below. Normal operation of the system should
include the following:
Persons coming in contact with wastewater, must immediately wash all exposed areas with disinfecting cleaner and contact your personal physician. Failure to
do so could result in severe sickness or death.
Only qualified service persons should open any access port or cover on the system. Hazards such as electric shock and Infectious organisms exist in these
areas. Persons coming in contact with wastewater, must immediately wash and disinfect all exposed areas and contact your personal physician. Failure to do so
could result in severe sickness or death.
CONTROL PANEL
When the control panel powered up, the system goes into AUTOMATIC run mode, the "Setting / Information" screen in the front face should
be blank.
Press
button once to reach each in the
"Setting / Information" screen. Line 1 to Line 4 are
display information only, Line 5 to Line 14 allows
changing certain parameters
AUTOMATIC MODE
Automatic mode is the standard running mode for the
system. When the panel is in the AUTOMATIC mode the
blower and pumps operate according to the inputs given
by the float switches, and the settings programmed into
the controller. There are two states of operation when the
system is in AUTOMATIC mode; FILTRATION MODE
(FLIT) and LONG TERM RELAXATION PERIOD (LTRP).
FILTRATION MODE (FILT)
The system is actively filtering wastewater and producing high quality effluent while in this state of operation. The system's
UP
the
position. The system's component operations are:
BLOWER:
DISCHARGE PUMP:
STATE:
Filtration Time:
Rest Time:
system's
®
OPERATION & MAINTENANCE
Always ON
(On timer) 30 MIN ON, 5 MIN OFF
FILT (Displayed)
Showing how long the system has been
filtering ( HH:MM) and counting up
Showing how long the system has been
resting (HH:MM), in the most recent
LTRP cycle
tank and as required by applicable codes.If a reuse tank is required for irrigation, it shall be located
after the BioBarrier® system. This tank shall also incorporate an overflow that allows excess reuse
water to be dispersed in a locally approved soil dispersal system or released into a sanitary sewer
system. If a potable water make up system is required for irrigation, it shall include a properly
designed backflow preventer that meets all applicable codes.
NORMAL OPERATING CONDITIONS
The BioBarrier
system's blower makes a constant humming noise, much
®
like a household refrigerator. Under normal conditions, the blower should
SOUND
last 5+ years without need for replacement. If an unusual noise is heard,
refer to the Trouble-Shooting Guide.
A musty, earthy-type of odor is normal. However, if a sewage odor (rotten
SMELL
egg smell) is detected, refer to the Trouble-Shooting Guide.
A properly loaded and operated BioBarrier
SIGHT
that looks like tap water. If the effluent is turbid, opaque, or suddenly
changes, refer to the Trouble-Shooting Guide.
system will produce effluent
®
BLUE FLOAT
01/01/01
OK
FILT
00:35
will be in
00:00
AUTO
02:56