10
Find a location for basestation mounting at
opposite corners of the tracked space. Mount
above head height and angle down 30-45°. The
basestation field of view is 120° in both axes
12
Avoid unstable mounting solutions or surfaces
that are prone to vibration.
14
Attach power cable to each basestation.
Connect them together with 50ft sync cable.
Plug in and turn on with switch on back of
unit. Later attach sync cable to ceiling.
50 ft sync cable
11
Max distance between units is 15ft/5M. Rough
linear dimensions of playspace are: 12 x 9ft/
4x3M. The area doesn't have to be a perfect
square. Taping off the play space can be useful.
13
Included hardware allows basestations to be
mounted to walls, ceilings, shelves or directly
to a standard tripod. A braced floor to ceiling
pole is also a good alternative. (see appendix)
BACK
15
Set one unit to A and one to B using MODE.
1) Long press: enter switching mode
2) Short press: toggle between modes
3) Long press: set mode
GREEN LEDS INDICATE UNIT IS WORKING
IGNORE BLUE AND PURPLE STATE
FRONT