OPERATOR'S MANUAL
App. Rate
01.20
l/m2
App. Rate +/-
00.10
l/m2

Nozzle spacing

167.0
mm

Number of nozzles

18
CSS 110 Automatic Sprayer Controller
11001-1679-201606

SETUP

Basic programming of constants is required prior to using the CSS 110.
To begin programming:
1. Press the OK button to power on. Wait for the Main screen to display.
2. Press the Menu button.
3. Use the + or - keys to scroll and select the desired constants to
change.
4. Press the OK button to confirm and program to desired setting.

CONSTANTS DEFINED

APP RATE
Application Rate displays in volume/area
– Press the OK button once. The decimal point will flash. Use the + or
- button to move to the desired position.
– Press the OK button to confirm and program to desired setting.
APP RATE +/-
The instantaneous increase or decrease of the application rate in volume/
area.
– Press + and - buttons at the Main screen to increase or decrease
the application by the amount displayed.
– Press the OK button to confirm and program to desired setting.
NOZZLE SPACING
Distance between nozzles.
– Press the OK button to move the decimal point using the + and -
buttons.
– Press the OK button to confirm and program to desired setting.
NUMBER OF NOZZLES
Total number of nozzles used.
– Enter total number of nozzles.
– Press the OK button to confirm and program to desired setting.
IMPORTANT: Replacing nozzles with different characteristics and
dimensions requires an update to the Nozzle Pressure
and Nozzle Flow screens.
SETUP / 5