TEST ALL GAS AND CONNECTIONS FOR LEAKS WITH A
From Gas Safety
Detector
5-20 lb Tank
Flapper Valve
ELECTRICAL
The blower fan is 12VDC and the power supply must be brought to the wire connectors of the fan
ON/OFF switch through the grommet installed.
A power converter jack (centre positive) from 120VAC to 12VDC is installed on the heater. A
120VAC to 12DC power converter (Dickinson Part No. 19-010) is used to operate the fan with
120VAC power. Plugged in to the jack the heater will use the 120VAC-power source. Removed
from the jack automatically switches the fan control to 12VDC.
Use of the blower fan is optional but greatly enhances heat output and hot air circulation.
www.ahoycaptain.com
SOAP SOLUTION
TYPICAL LPG ON-BOARD SYSTEM
Solenoid Valve
Pressure Gauge
Secured
Bottle
Min. 1/2" I.D. Vent
Pressure
Regulators
Manual
Shut-Off
NEWPORT
HEATER
SEA-B-QUE
BARBEQUE
COOK STOVE
VENTED ENCLOSURE
8