{카테고리_이름} Alpha ESS M4856-P에 대한 빠른 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Alpha ESS M4856-P 7 페이지. Battery module
Positive power line wiring
Step7
DIP Switch
Step10
Communication board DIP switch configuration:
Confirm that the battery closest to the inverter is
1
number 1 battery and so on. The maximum
number of parallel batteries is 6.
2
The direction of the last DIP switch of the battery
is configured according to the black mark
position of the No. 6 figure, that is, the last
battery dial switch 2 is up and the other battery
dial switches are all down.
When the number of batteries is between 2 and
3
6 sets, the dial switch configuration is operated
according to the sequence.
Negative power line wiring
Step8
Connect Communication Line
Step9
Mounting Appearance Parts
Step11
The mode of disassembly of step 2 of restoration:
A
Pull the top two guide rods into the housing.
B