Alpha ESS Smile5-BAT 설치 매뉴얼 - 페이지 8

{카테고리_이름} Alpha ESS Smile5-BAT에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Alpha ESS Smile5-BAT 10 페이지. Battery module
Alpha ESS Smile5-BAT에 대해서도 마찬가지입니다: 빠른 설치 매뉴얼 (7 페이지)

Alpha ESS Smile5-BAT 설치 매뉴얼
the discharging function will not be allowed until the battery is fully charged
for at least once and the SOC is corrected.
 In the case of parallel mode or work mode, if Protection 09 appears and the
power button is pressed 5 times within 10 seconds, the BMS will be forced to
turn on MOS of discharge so that the battery voltage can be detected by the
inverter and the battery can be charged.

5. Emergency Situations

AlphaESS cannot guarantee Smile5-BAT absolute safety.
Fire
In case of fires, make sure that the following equipment is available near the system.
 SCBA (self-contained breathing apparatus) and protective gear in compliance
with the Directive on Personal Protective Equipment 89/686/EEC.
 Novec 1230, FM-200, or dioxide extinguisher.
NOTE
ABC extinguishers are not effective when the battery pack is on fire.
Batteries may explode when heated above 150°C. If possible, move the battery
pack to a safe area before it catches fire.
Leaking Batteries
If the battery pack leaks electrolyte, avoid contact with the leaking liquid or gas. If
one is exposed to the leaked substance, immediately perform the actions described
below.
 Inhalation: Evacuate the contaminated area, and seek medical attention.
 Contact with eyes: Rinse eyes with flowering water for 5 minutes, and seek
medical attention.
Alpha ESS Co., Ltd.
Your Smarten Energy