FUSE PROTECTION
Please note that a standard AC fuse should NOT be used in a DC circuit. The fuse must
be SPECIFICALLY labeled for DC applications. For most larger motor applications, a
600A fuse will be sufficient. Application-specific fuses can be ordered directly from EPC.
Also note that standard 125-volt and 240-volt DC circuit breakers (such as the AirPax
JLM-1-1RLS5-30140-200) will NOT function correctly because of the high voltage present
when the motor's windings are discharged during normal operation. If using a circuit
breaker, it must have a DC break rating higher than 600 volts.
NO
CONTACTORS
A pair of contactors, or some other type of high-speed mechanical disconnect should be
installed near the power supply. This not only allows for easy servicing, but can protect
the motor and controller in the event of a short or system failure. Contactors are
REQUIRED for all electric vehicles running DC motors.
CONTROLLER PROTECTION
YES
Pictured is a Curtis SW-200 Contractor. Contactors should
have a continuous rating of at least 200 amps, with a surge
capacity of about 1000 for this controller. Magnetic
blowouts are required.
NO