Dictator E8 기술 매뉴얼 - 페이지 16
{카테고리_이름} Dictator E8에 대한 기술 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dictator E8 19 페이지.
Technical Manual E8
IV/1 Codes in the Display
of the E8 - cont.
Page 05.023.16
IV. Diagnostics/Indication of Errors - cont.
Error
Meaning
Code
continuation
T02
Error due to exceeding the
maximum allowed current
(this happens whenever the
control system operates more
than 30 seconds with the
maximum current).
FCd
Problems with recognising
the position: gate does not
stop in the open position,
but closes immediately.
-
© DICTATOR Technik GmbH • Gutenbergstr. 9 • 86356 Neusäß • Germany
Tel. +49(0)821-24673-0 • Fax +49(0)821-24673-90 • E-mail [email protected] • 20200703
Possible Causes /
Measures
Motor cannot move the gate as the
force needed is too high (e.g. higher
friction due to dirt).
Press RESET button
Now the control system is ready to
work again.
- When using limit switches possible
malfunction of these switches (contacts
of the limit switches opened at the
same time)
- Parameter P-b is adjusted to limit
switches, but an operator with
encoder is connected.
- Parameter P-b is adjusted to an
operator with encoder, but an
operator without encoder is connected.
- Check, if all required bridges
according to point II/4 have been set
(see page 05.023.6)
- Check the fuse F2 above the clamps
43/44