Troubleshooting
Performance problems often result from little things that you can fix yourself, Please read through this chart for a
_ossible solution if a problem occurs.
PROBLEM
No ammeter reading.
Circuit breaker in
charger cycles on and
off with a clicking
sound in MANUAL
setting.
Ammeter reads less
than selected charge
rate when charging.
POSSIBLE CAUSE
Clamps not making good
connection,
2-amp charge rate.
No AC power reaching
charger.
Shorted battery clamps.
Shorted battery.
Charger leads reversed
on battery.
Extension cord too long or
gauge to small.
Battery has weak cell or
sulfated plate.
SOLUTION/REASONS
Check for poor connection
at battery.
Make sure clamps
and posts are clean. Battery may not accept an AUTOMATIC
charge if severely discharged.
Use MANUAL setting, see
"Using your battery charger" on page 6.
Ammeter needle will indicate little activ_ at the 2-amp charge
rate.
Check AC outlet and extension cords for loose fitting plug.
Check for open fuse or circuit breaker supplying AC outlet.
Separate the clamps. Circuit breaker cycles when current
draw is too high.
Check for worn cables and replace if needed.
Have a Sears technician test the battery.
Correct connections.
Use shorter or heavier extension cord.
Sulfated battery will eventually take a normal charge if left
connected.
If the battery will not take a charge, have it
tested by a Sears technician.
Battery is partially
Continue charging battery.
charged.
Charger makes a loud
Transformer laminations
Continue charging. Buzz is not abnormal.
buzz or hum.
vibrate (buzz).
Shorted diode (hum).
Short start cycle
when cranking
engine.
Drawing more than 75
amps for a period equal to
or less than 7 seconds.
Failure to wait for 4
minutes (240) seconds)
between cranks.
Have charger tested by qualified technician.
i Crank time varies with the amount of current drawn from
the charger. If cranking draws more than 75 amps, crank
time may be less than 7 seconds.
Wait 4 minutes before next crank.
If the above solutions do not eliminate the problem.,,
call toll-free from anywhere in the U.S.A.
1-800-SEARS-64
(1 -S00-732-7764)
7 AM to 4:30 PM CST Monday through Friday