Do not damage or cut the wire insulation (covering) during installation. Do not permit wires to contact any surface
having a sharp edge, as this may damage the wire insulation and create the risk of electrical shock. FAILURE TO
FOLLOW THIS WARNING MAY LEAD TO DEATH, SEVERE INJURY, OR PROPERTY DAMAGE.
N
otee:
When power is turned on, the luminaires default to 100% on unless a different control signal is present.
Control Wiring
Always turn power to fixture OFF before performing any work on control wiring. Turn transmitters off before working
on main control lines. Performing any work on control connections while fixtures are receiving the signal may
result in transient or fluttering control signals which can cause damage to the luminaire. FAILURE TO FOLLOW THIS
WARNING MAY LEAD TO LUMINAIRE INTERNAL DAMAGE AND FAILURE.
Control Standards
All control work shall conform to ANSI E1.11 – 2008 (r2013), USITT DMX512-A, Asynchronous Serial Digital Data Transmission
Standard for Controlling Lighting Equipment and Accessories. At a minimum DMX cable shall be 1-pair (24AWG, 7x32
Stranding) Twisted (minimum of 4.8 twists/foot), Shielded, minimum of 100 ohms impedance, and <25pF/ft. Capacitance.
Use caution when connecting any 24AWG wires as they are more prone to breaking. 24 AWG may be used in
terminal blocks. If wire will be connected with wire nut, wago connector, or other mechanical splices, use 22 AWG
wire.
LANDBURST CONTROLSe: Plug in the control lines via the 3-pin XLR whips provided with the luminaire. Use the male
●
●
XLR as the DMX input and the female as the DMX output. Use an RDM controller to set the DMX start channel(s) of the
fixture.
8
EATON
IB528002EN
Male DMX In
Figure 6.
Installation instructions rev 20171011
WARNING
WARNING
WARNING
Female DMX
Out