DieHard 28.71495 운영자 매뉴얼 - 페이지 12

{카테고리_이름} DieHard 28.71495에 대한 운영자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DieHard 28.71495 14 페이지. 750 watt power inverter

DieHard 28.71495 운영자 매뉴얼
8.

If ThE INvERTER fUSE BLOWS

Your power inverter is fitted with a fuse, which should not have to be replaced under
normal operating conditions. A blown fuse is usually caused by reverse polarity or a
short circuit within the device or equipment being operated.
If the fuse does blow, take the inverter to a qualified technician for repair.
9.

TROUBLEShOOTINg

PROBLEM
Alarm is On
REASON
Display shows . Device
has a short circuit or
demands too much surge
power.
Display shows . 12-volt
battery is too low.
Display shows voltage in
between 10.5 and 11.0-volts.
Display shows . 12-volt
voltage is too high.
Display shows .Device
demands more than the
inverter's continuous power
rating.
• 9 •
SOLUTION
Cycle the inverter power OFF
and ON.
If problem persists, use a
larger inverter or a smaller
device.
Remove the defective device.
See warranty and call
Customer Service 1-800-732-
7764 (Hours 7:00 am to 5:00
pm CST).
Recharge/replace battery
12-volt battery is low.
Recharge/replace battery.
The inverter will automatically
shut off after battery voltage
reaches 10.5-volts.
If in a vehicle, repair/replace
the alternator or charging
system.
Use a properly sized and
rated 12-volt battery.
If the input voltage returns to
15-volts or less, the inverter
will automatically restart.
Cycle the inverter power OFF
and ON.
If problem persists, use a
larger inverter or a smaller
device.