IZAR RDC Battery
6 MAINTENANCE
IZAR RDC BATTERY requires no specific maintenance.
Do not clean it with solvents or abrasive cleaners, as these would damage the plastic shell.
If necessary, use a damp cloth or sponge.
Storage: The product should be stored in a dry place at temperatures between: - 20°C ... + 70°C.
Prolonged storage at high temperatures may cause significant loss of autonomy.
6.1 BATTERY PACK REPLACEMENT
Only use the Diehl Metering referenced battery pack!
Caution: Risk of explosion if the battery pack is replaced by an incorrect battery
pack type!
Caution: if an external power supply is used, disconnect the connector before
any housing handling
The battery pack can be replaced directly on site. The following steps should be followed:
1) Open the housing
2) Disconnect and remove the battery pack
3) Install the new battery pack
4) Reinstall the cushioning foam
5) Connect the new battery pack
6) Close the housing
Note: during battery pack replacement, configuration settings are kept in non-volatile memory
without risk of data loss.
For battery pack recycling, please refer to chapter "Recycling".