Check transmission lines for breaks, loose or missing hardware, chafing and so forth.
The transmission line itself should be visually checked for signs of changed
alignment, undue stressing and loose coupling clamps and hardware.
Inspect the antenna mounting hardware for tightness.
Observe the dry nitrogen gas/dehydrated-compressor air usage as an indication for
system leaks.
Note:
Whenever the system has been open for repair purge with dry nitrogen gas
or dehydrated-compressor air as described in section E of the Installation
instructions. Never operate the system under power until all moisture has
been purged. Otherwise permanent damage may occur to the entire system,
including the transmitter and transmission line.