Olympus PT-E03 사용 설명서 - 페이지 37

{카테고리_이름} Olympus PT-E03에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Olympus PT-E03 41 페이지. Underwater case for digital camera e-410/e-400

Q5:
: What cautions must be observed when opening and closing the Case?
A5:
: Pay special attention to the following items.
1 Do not open and close the Case at locations with water spray or sand spray.
2 Wipe off all waterdrops from the gap between the front lid and the rear lid and around
projections and recesses such as the buckles.
When this is not done, entry of waterdrops into the Case is to be feared at the time of
opening and closing.
3 When opening the Case, take care that no water will drip from your hair or body into the
Case or onto the camera.
4 When the case is open, examine the O-rings and the O-ring contact surfaces on the front
lid for foreign matter such as hair, fiber, and grains of sand. Remove these if present. Also
examine the O-rings used for connection of the case and port.
5 Do not touch the camera or the image storage if your hands are in contact with seawater.
6 If you should detect waterdrops or other signs of water leakage while shooting, immediately
end the dive, perform the water leakage test again, and confirm that there is no leakage. If
the camera is wet, wipe off any moisture and check the operation.
Q6:
: How should the Case be handled after use?
A6:
: After use, take out the camera as soon as possible and wash the Case with pure water. In case
of use in the ocean, it is effective to immerse the Case for a certain time in pure water to remove
any salt. Operate the buttons and levers under water to turn the shafts and wash off any salt.
After washing, use a dry cloth without any salt on it to wipe off any moisture and dry the Case
in the shade. Do not use hot air from a hair drier or the like and do not dry the Case under direct
sunlight. Exposure to high temperatures or direct sunlight may cause deformation,
discoloration or breakage of the Case and deterioration of the O-ring. Wipe the inside of the
Case with a lint-free soft cloth. Remove the O-ring, wipe off any salt, sand, dust, etc., and also
clean the O-ring groove and the O-ring contact surface in the same way and then dry them.
When an object with a sharp tip is used to remove the O-ring from the groove, the O-ring may
be damaged and water leakage may be caused. Always use the accessory pick for O-ring
removal.
Q7:
: How can I check for water leakage?
A7:
: For confirmation, perform the advance test and the final test after loading the camera. The
advance test with immersing the Case without the camera to the intended use depth to check
for water leakage is the most accurate test, but when this is difficult, it is safer to perform this
test even at a depth of 1 m or in a bathtub. The final test also can be performed in a bathtub or
a bucket.
Q8:
: What are the causes for entry of water?
A8:
: The main causes for the entry of water are shown below. Please check with special care.
1 Forgetting to install the O-ring
2 The O-ring is partly or completely outside the groove.
3 Damage, deterioration, or deformation of the O-ring
4 Sand, fibers, hair or other foreign matter on the O-ring
5 When foreign matter (sand, fiber, hair, etc.) is stuck to the O-ring grooves or O-ring contact
surfaces.
6 Catching of the strap, the bag of silica gel, etc. at the time of sealing the Case.
7 Throwing the Case from a boat into the water, jumping with the Case into the water, or other
sudden application of strong forces onto the Case. When entering the water, hand the Case
over quietly or avoid impacts in other ways.
En
EN 36