Olympus PR-V416Q 매뉴얼 - 페이지 2
{카테고리_이름} Olympus PR-V416Q에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Olympus PR-V416Q 18 페이지. Single use cannula v
The Innovative V-System Exchange Capability Makes
Olympus' ERCP Cannulae Even More Efficient
The Innovative V-System Design Lets You Proceed
with Confidence and Efficiency
The V-System is a complete system that integrates Olympus endoscopes and EndoTherapy devices. The revolutionary
V-System design offers the option of guidewire manipulation by the physician or the assistant, allows easier exchange
of catheters, and enhances cannulation capability.
C-Hook
Now endoscopists have the option to
manipulate guidewires and devices.
The convenient C-Hook allows the device handle to be attached to the endoscope's control section, putting
it within easy reach of the endoscopist. With the device handle right at hand, the endoscopist can maneuver
the guidewire, inject contrast media, and manipulate the handle — all while keeping a grip on the scope
control section.
V-Marking
Indicates when to raise and lower
the V-Groove forceps elevator.
The exclusive V-Marking is located on the proximal side of the sheath. When this marking reaches the
channel port on the scope's control section, it indicates that the device tip has reached the distal end of
the scope and the V-Groove forceps elevator may be lowered. When withdrawing the device from the
scope, the same marking indicates when to raise the elevator to lock the guidewire.
Excellent visibility under
fluoroscopy
The platinum marking at the distal
end ensures that the tip is clearly
visible under fluoroscopy.
Wide selection of cannulae
A full line-up of 8 models of different
tip designs and diameters is available
to meet every clinical requirement.
Smooth cannulation of
even minor or
constricted papilla
The X-PressV's cross-cut round
tip is not only ideally suited for
smooth cannulation of the papilla
Short taper (PR-V414Q)
of Vater, but is also equally effective
for cannulation of the minor or
constricted papilla.
Long taper (PR-V420Q)
Standard position of
During guidewire
X-PressV cannula
insertion or fluid injection
Expanded guidewire
compatibility
Compatible with guidewires of
various sizes.
Comprehensive distal
marking system
Cannulation depth is indicated by
markings at 3mm intervals at the
distal end.
Single-use design for
convenience and reliability
All the cannulae in this line are
designed for single use only.
Standard (PR-V416Q)
Short taper (PR-V418Q)
Taper (PR-V434Q)
Taper (PR-V435Q)
Slit (PR-V427Q)
Ball Tip (PR-V223Q)