Axminster Trade 105781 원본 사용 설명서 - 페이지 5

{카테고리_이름} Axminster Trade 105781에 대한 원본 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Axminster Trade 105781 16 페이지. Cyclone extractors
Axminster Trade 105781에 대해서도 마찬가지입니다: 원본 사용 설명서 (16 페이지)

Axminster Trade 105781 원본 사용 설명서
Keep the particle filter clean. The machine relies on its
ability to 'blow' air through the filter, to generate good
suction. If the particle filter starts to clog, this reduces the
air flow and hence the machine becomes less efficient.
The particle filter can be cleaned, by removing the rear
filter cover (20) and using a vacuum cleaner, clean the
inside of the filter as illustrated on page 17.
Be aware that in dry air periods or areas, the movement
of the air through the machine can generate static
electric fields. These are not normally a problem as the
machine is bonded together via its construction and
the whole is earthed back through the electrical supply;
problems can occur with isolated items, such as stands
Code
Model
Rating
Power
Supply Circuit
Air Flow
Sound Pressure
Level [Uncertainty K]
Static Pressure
Filter Performance
Filter Surface Area
Container Volume
Inlet
Overall L x W x H
Weight
Please read through the section entitled Parts identification and Description, this will enable you to more readily
identify those parts of the cyclone extractor.
Please note: some of this assembly procedure is best accomplished by two persons. Although
the tasks are not impossible, some of the items are heavy and awkward, and a mishandling
error could cause injury. Please think about what you are doing, your capabilities and your
personal safety. We have added the 'two person symbol' to any operation that we recommend
should be a two person task.
Unpack all the boxes and check all the components listed in the "What's Included" section. If any parts or components
are missing, please contact our Customer Services Department using the procedures and telephone numbers listed
in our catalogue.
Please note: on occasions the packing list is not strictly adhered to. Please check all the boxes, packets
etc. to make sure that all the parts have been accounted for.
PLEASE RECYCLE ANY UNWANTED PACKAGING RESPONSIBLY!
SPECIFIC SAFETY FOR DUST EXTRACTORS
105781
AT154CEH 1.5HP
Trade
1.1 kW 1Phase
16 Amps (Type C Breaker)
1,600 m³/hr @ 150 mm
76 dB(A)
2,440 Pa
99.97% >0.3 micron
2.5 m²
110 litre
1 x 150 mm or 2 x 100 mm
1,120 x 700 x 1,780mm
117kg
or hosing that are insulated from the ground (standing
on rubber feet?, suspended in the air etc).
If possible, try to connect everything together electrically,
to eliminate static shocks.
(Use the integral metal coil in flexible plastic hosing to
connect units together).
Try to route the power cable and the hosing away from
busy walkways.
allow the inlet to become 'dead ended' , or block
Do not
or restrict the outlet, this puts undue strain on the motor
and can lead to overheating.
105783
AT176CEH 2HP
1.5 kW 1Phase
16 Amps (Type C Breaker)
1,715 m³/hr @ 178 mm
76 dB(A)
2,490 Pa
99.97% >0.3 micron
168 litre
1 x 178 mm or 3 x 100 mm
1,120 x 700 x 2,080mm
ASSEMBLY INSTRUCTIONS
5

SPECIFICATION

AT357CEH 3HP
Trade
2.2 kW 1Phase
16 Amps (Type C Breaker)
3,700 m³/hr @ 200 mm
99.97% >0.3 micron
2.5 m²
1 x 200 mm or 3 x 100 mm
1,370 x 790 x 2,030mm
127kg
105784
Trade
77 dB(A)
2,735 Pa
4.35 m²
198 litre
155kg