Axonn AXC550 설치 지침

{카테고리_이름} Axonn AXC550에 대한 설치 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Axonn AXC550 2 페이지. Rf transceiver

Axonn Corporation
AXC550
Transceiver
Users Manual
RF Transceiver Installation Instructions
The AXC550 Transceiver is a member of our Spread Spectrum RF family of products.
This transceiver should only be installed by qualified service personnel.
The transceiver detects level, low battery or other data signals from the external
binary inputs and broadcasts that data to the system's host receiver.
MOUNTING LOCATION
The AXC550 Transceiver is a module as defined by the FCC and therefore must be
mounted to another host device in order to function.
NOTICE TO CUSTOMER
Any Axonn customer incorporating the AXC550 transceiver module into its own
product must have an external notice affixed to its product. This notice must be
placed in a conspicuous location and can use wording such as: "Contains FCC ID:
L2VAXC550" or "Contains Transceiver Module FCC ID: L2VAXC550". Any similar
wording that expresses the same meaning may be used.
INSTALLATION INSTRUCTIONS
1. Supply the transceiver with DC power by inserting two 3.6 Volt batteries into the
battery holder on the customers host application circuit board.
2. The unit will come pre-programmed with Transceiver ID and Property Code.
However, the customer does have the option of field programming the unit.
3. When installing the AXC550 you should avoid areas near screens, metal window
frames, circuit breaker boxes, air conditioners and heaters if a suitable location for the
unit may be found elsewhere.
!
CAUTION:
This device is required to comply with FCC RF exposure requirements for mobile
transmitting devices. The FCC requires that the antenna(s) used for this transmitter
must be installed to provide a separation of at least 20 cm (8 inches) from all persons
and must not be co-located or operating in conjunction with any other antenna or
transmitter.
TESTING THE TRANSCEIVER
Following system installation, system testing is mandatory. This should be performed by
locating the AXC550 in its final location and powering up the unit. On initial power-up,
the AXC550 will send out RF messages every 4 seconds or more depending on
programming. This will establish communications with the Host receiver and the
information collected will then be used to judge system performance.