F A U L T
⁄ Insufficient water
⁄ Crossflow, hot water being forced into
cold water pipe, or vice versa, when
mixer is closed
⁄ Spout temperature does not
correspond with temperature set
⁄ Temperature regulation not possible
⁄ Safety stop button not operating
⁄ Valve stiff
⁄ Shower or spout dripping
C A U S E
⁄ Supply pressure inadequate
⁄ Regulator filter dirty
⁄ filter insert shower dirty
⁄ Backflow preventers dirty or leaking
⁄ Thermostat has not been adjusted
⁄ Hot water temperature too low
⁄ thermo cartridge calcified
⁄ For new installations: basic body incor-
rectly connected (should be: cold right,
hot left) or installed with 180º rotation
⁄ Spring defective
⁄ Button calcified
⁄ Shut-off unit damaged
⁄ Dirt or sedimentation on valve seat,
shut-off unit damaged
0 3
R E M E D Y
⁄ Check water pressure (If a pump has
been installed check to see if the pump
is working).
⁄ Clean filter in front of the mixer and on
the MTC-thermo cartridge
⁄ Clean filter insert between shower and
hose
⁄ Clean backflow preventers, exchange
if necessary
⁄ Adjust thermostat
⁄ Increase hot water temperature to
42 ºC to 65 ºC
⁄ Exchange thermo cartridge
⁄ Install function block turned through
180º
⁄ Clean spring and/or button, exchange
if necessary
⁄ Exchange shut-off unit
⁄ Clean or exchange shut-off unit
A S S E M B L Y (see page 06)