1. Remove the control panel if fitted.
2. In the control panel slot there is a little hole.
Press the retaining lever inside.
3. Remove the cover.
1. Stripp off the insulation from the motor cable and
mains cable. Twist the screen wires to bundles.
2. Make suitable holes to motor and mains cable
grommets.
3. To minimise radio frequency interference (RFI) at the
motor end screen 360° earthing at cable lead-through.
STOP!
CHECK THE INSULATIONS OF MOTOR, AND MAINS AND MOTOR CABLE.
MOTOR AND MAINS CONNECTION
1.Lead the motor and mains cables through the
clamp plate.
2. Connect the motor cable to the terminal block
marked U2 V2 W2 on the right hand side of the
ACS 400.
3. Connect the mains cable to the terminal block
marked U1 V1 W1 on the left hand side of the
ACS 400.
4. ENSURE PROPER EARTHINGS.
ACS 400 does not carry internal fusing.
NOTE!
Please ensure correct fuses are installed at the supply distribution board.
See ACS 400 User's Manual for correct fuse sizes.