Axor 35280 7 Series 사용 지침/조립 지침 - 페이지 3
{카테고리_이름} Axor 35280 7 Series에 대한 사용 지침/조립 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Axor 35280 7 Series 16 페이지.
S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
D I M E N S I O N S (see page 16)
F L O W D I A G R A M (see page 4)
F A U L T
⁄ Head shower extremely leaky
A S S E M B L Y (see page 8)
max. 0,6 MPa
0,15 - 0,4 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C ⁄ 4 min
C A U S E
⁄ Head shower soiled ⁄ scaled
S P A R E P A R T S (see page 14)
XX = Colors
00 = Chrome Plated
34 = Brushed Black Chrome
99 = Polished Gold-Optic
C L E A N I N G (see page 10)
I N S T A L L A T I O N E X A M P L E
i
(see page 4)
R E M E D Y
⁄ Clean ⁄ descale head shower (see
page 10