Axor Massaud 사용 지침/조립 지침 - 페이지 3
{카테고리_이름} Axor Massaud에 대한 사용 지침/조립 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Axor Massaud 12 페이지.
S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Children as well as adults with physical, mental and ⁄or
sensoric impairments must not use this product without
proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive
body parts (such as your eyes). An adequate distance
must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
⁄ The mesh washer must be insert to protect the shower
against incoming dirt by pipework. Incoming dirt leads
to defects or⁄and can damage parts of the shower;
such caused faults voids all liability and guarantee
claims.
F A U L T
⁄ Insufficient water
⁄ Mixer stiff
⁄ Mixer dripping
⁄ Water escaping in area of swivel
spout
⁄ Instantaneous heater didn't work
⁄ Hot water temperature too low
A S S E M B L Y (see page 04 )
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
C A U S E
⁄ Shower filter seal dirty
⁄ Cartridge defective, calcified
⁄ Cartridge defective
⁄ O-ring defective
⁄ Shower filter seal dirty
⁄ Flow limiter in handshower isn't re-
moved
⁄ Hot water limiter incorrectly set
(1 MPa = 10 bar = 147 PSI)
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 05 )
To adjust the hot water limiter. Using a hot water
limiter in combination with a continuous flow
water heater is not recommended.
Hot and cold supplies are reversed
(see page 03 )
D I M E N S I O N S (see page 06 )
F L O W D I A G R A M (see page 08 )
S P A R E P A R T S (see page 12 )
S P E C I A L A C C E S S O R I E S
(order as an extra)
⁄ extension 60 mm #97686000 (see page 12)
C L E A N I N G (see page 09)
O P E R A T I O N (see page 08 )
R E M E D Y
⁄ Clean filter seal between shower and
hose
⁄ Exchange cartridge
⁄ Exchange cartridge
⁄ Exchange O-ring
⁄ Clean filter seal between shower and
hose
⁄ Remove flow limiter
⁄ Set hot water limiter
0 3
EN
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 60°C
70°C ⁄ 4 min