Arcam SA10 사용자 지정 설치 참고 사항 - 페이지 12
{카테고리_이름} Arcam SA10에 대한 사용자 지정 설치 참고 사항을 온라인으로 검색하거나 PDF를 다운로드하세요. Arcam SA10 20 페이지. Ip/serial programming interface and ir remote control commands
DC offset (0x51)
Request the output DC offset status.
Example
Command/response sequence for requesting the DC offset status where the
result is no DC offset:
Command:
0x21 0x01 0x51 0x01 0xF0 0x0D
Response:
0x21 0x01 0x51 0x00 0x01 0x00 0x0D
Short circuit status (0x52) (SA20 only)
Request the output short circuit status.
Example
Command/response sequence for requesting the short circuit status, where
the result is no short circuit:
Command:
0x21 0x01 0x52 0x01 0xF0 0x0D
Response:
0x21 0x01 0x52 0x00 0x01 0x00 0x0D
12
COMMAND:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x51
Dl
0x01
Data
0xF0 – Request DC offset status
Et
0x0D
RESPONSE:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x51
Ac
Answer code
Dl
0x01
Data
0x00 - OK
0x01 - DC offset detected
Et
0x0D
COMMAND:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x52
Dl
0x01
Data
0xF0 – Request short circuit status
Et
0x0D
RESPONSE:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x52
Ac
Answer code
Dl
0x01
Data
0x00 - No short circuit detected
0x01 - One of the channels has short circuit fault
Et
0x0D