Axxent AX 1400TS 사용자 설명서 - 페이지 3
{카테고리_이름} Axxent AX 1400TS에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Axxent AX 1400TS 4 페이지. Professional power amplifier
user manual
models AX-1121TS / AX1240TS / AX 1400TS
amplifier controls and connectors on the rear
At the far left you see a large power switch and below an IEC
connector with fuse holder. Intentionally we do not use an inte-
gral power cable so that the amplifier may be removed from a
19" rack easily. The IEC power cable is always included in the
amplifier box, when shipped.
If you should ever encounter an amplifier problem, i.e. you have
switched it on and the green power led does not light, its fuse
may be defective. A defective fuse should be changed by a
qualified service technician. Power fuse values are as follows:
AX1121T and AX1240T slow blow 4 A; AX1400T slow blow 6.3 A.
Fuse type is 5 mm by 20 mm.
output connectors, constant voltage
To the right of the power switch you can see the green Euro-bloc
or Phoenix connector. This connector is used for the constant
voltage outputs and indicated 50-, 70- and 100 volts. Standard
constant voltage in Europe is 100 volts.
The Eurobloc is a solderless connector that uses screw
terminals to connect wires. Once the wires are installed, the
entire assembly is plugged into a matching socket in the elec-
tronic device. Euroblocs are more convenient than terminal
strips because they may easily be disconnected if the need
arises.
axxent e.K. • Technologiezentrum Herzbachtal • Zum Wartturm 15 • 63571 Gelnhausen
Fon: +49-6051-9165584 • Fax: 9165585 • [email protected] • www.axxent.de
3