CIRCLE FITNESS R8 서비스 매뉴얼 - 페이지 9
{카테고리_이름} CIRCLE FITNESS R8에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. CIRCLE FITNESS R8 16 페이지.
CIRCLE FITNESS R8에 대해서도 마찬가지입니다: 서비스 매뉴얼 (9 페이지), 서비스 매뉴얼 (20 페이지)

Item
Error Message
1.
MV VOLT OVERLOAD
2.
CMP CURR OVERLOAD
3.
CMP CURR OVERCURR
4.
SHORT CIRCUIT
5.
CURRENT STATE NG
Document:
Service Manual
Description:
Elliptical/Upright Bike/ Recumbent Bike
Model:
E7/B8/R8
Descriptions
CAUSE: The generator output voltage is overloaded.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
CAUSE: The output current of the generator is over 3amps
for 3 seconds.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
CAUSE: The output current of generator is over 3.5amps
for 1 second.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
CAUSE: The IGBT of generator is short circuit.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
CAUSE: The output circuit of the generator is abnormal or
the coil did not connect to the controller.
SOLUTION:
- Check the coil connection.
- If coil connection is correct, replace the generator.
9
Display Type:
LED
Page:
9
of 16
Release Date:
2017/08/31