Axxeron HESCH HE 5710 사용 설명서 - 페이지 8
{카테고리_이름} Axxeron HESCH HE 5710에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Axxeron HESCH HE 5710 19 페이지. Solenoid valve controller
Explosion Prevention! (for ATEX approved devices only!)
This device (the version with the Makrolon housing) is suitable for
operation in explosion Zone 22 with the lid closed (where an explosive
atmosphere may arise due to electrically conductive dusts).
Prior to opening the device, one must ensure that there are no explosive
ambient conditions, such as dust formation. The special regulations
governing operation in an Ex-area must be observed.
Fuse failure!
First determine the causes for the failure and remove them.
Only use fuses which have the same specification as the original type as a
replacement.
Repaired fuses or short circuiting are not permissible.
Troubleshooting!
At the beginning of troubleshooting, all possible sources of faults on
additional devices or supply lines (measuring lines, wiring, downstream
devices) should be taken into consideration. If the fault is not found after
checking these points, we recommend sending the device to the supplier.
Decommissioning!
Switch off the power supply on all poles if the device is to be
decommissioned. Secure the device against being unintentionally
switched on!
If the device is linked to other devices and/or equipment, consider the
impacts and take appropriate precautions before switching it off.
8
HE 5710 / 5711 Operating Instructions
# 371814 | Version 1.4