Axxeron HESCH HE 5711 사용 설명서 - 페이지 11

{카테고리_이름} Axxeron HESCH HE 5711에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Axxeron HESCH HE 5711 19 페이지. Solenoid valve controller

3.2

Display and Operating Elements

Symbols
Meaning
HE 5710 / 5711 Operating Instructions
# 371814 | Version 1.4
Name plate
Display and Operating Elements
RUN
LED green
Lights up, if the operating voltage is applied and the processor is active
CYCLES
Rotary coding switch
Determines the number of cycles (1...9). The rotary coding switch setting 0,
deactivates the cyclic cleaning.
PULSE
LED yellow
Lights up during the actuation time (pulse) of the valves
Potentiometer for pulse time setting between 0.02...1.2 s
PAUSE
LED yellow
Lights up from pause to actuation (pulse) of the next valve. Even during
longer pause times, the state of the controller is recognisable.
Potentiometer for pause times from 1...270 s
Button TEST
Pressing the button once, starts pulse and pause of the next valve.
Pressing the button one more time, cancels the pause of the active valve or
starts the next valve.
Pressing the button for more than 2 s, starts a cleaning for the set cycle. If
the number of cycles is 0, the cleaning continues as long as the button
TEST is pressed.