ABB Jokab Safety Safeball JSTD1 원본 사용 설명서 - 페이지 9

{카테고리_이름} ABB Jokab Safety Safeball JSTD1에 대한 원본 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. ABB Jokab Safety Safeball JSTD1 16 페이지. One/two hand enabling device
ABB Jokab Safety Safeball JSTD1에 대해서도 마찬가지입니다: 원본 사용 설명서 (15 페이지)

ABB Jokab Safety Safeball JSTD1 원본 사용 설명서

Minimum mounting distances and requirements for two hand device

Warning! Follow the below instructions to avoid severe personal injury.
A Safeball must be mounted at a minimum distance to the edge of the mounting surface in order to prevent the
system being defeated and the device being activated either intentionally or unintentionally with a part of the body
other than the hands.
If the Safeball is mounted on e.g. a ball joint or any other solution where the Safeball can be moved, the distance to
the closest wall must also be considered. This distance is determined by the mount, but the Safeball must never be
able to reach the wall in any position.
To accomplish a two hand device type IIIC according to EN 574, the following additional requirements must be met:
Two one-hand devices must be used and connected to the same safety monitor.
The two devices must be mounted at a minimum distance between each other in order to prevent both of
them being operated with one hand (see measurements in the figure below).
180
Warning! The minimum safety distance varies greatly as there are many ways to mount JSTD1 units. It is essential
that mounting prevents the system being defeated either intentionally or unintentionally.

Two hand device function description

The safety monitor must be programmed / parameterized to monitor the simultaneous action of both the two
channels in the devices and also the simultaneous action of the two devices. The maximum time between
activation of the two channels in each device must be 0.5 seconds and the maximum time between activation of
the two devices must also be 0.5 seconds.
Safeball #1
Safeball #2
2TLC172180M0201, rev. A
2011-10-20
(mm)
120
Minimum mounting distances
1oo2 monitor with time limit 0.5 s
1oo2 monitor with time limit 0.5 s
Two hand device function description
1oo2 monitor with time limit 0.5 s
9
www.jokabsafety.com