ABB PME120-AN 사용 설명서 - 페이지 5

{카테고리_이름} ABB PME120-AN에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. ABB PME120-AN 18 페이지. Electrical part-turn actuator

ABB PME120-AN 사용 설명서

7. Lubrication

Prior to delivery the actuator is filled with 2.5 l oil in factory.
1)
Fig. 1:
Min. oil quantity;
approx. [l]
Min. oil level [mm]
under inspection
screw
Table 3: The arrow indicates the position of the inspection screw
actuator, replace the highest inspection screw with the separately delivered vent screw.

7.1 Lubricants

Actuator type
PME 120AI
(with integrated electronic unit)
PME 120AN
(for separate electronic unit)
Table 4:

8. Mounting

8.1 Actuator check

- Is the actuator filled with the appropriate oil type?
- Is enough oil in the actuator?
- Did you fasten the separately delivered vent screw in the highest bore (depending on the mounting
orientation)?
- Has the actuator integrated or separate electronic unit?

8.2 Mounting orientation

All mounting orientations seen in Figure 2 are permissible. To facilitate mounting and maintenance,
however, it is recommended to use orientation IMB 3.

8.3 Mounting instructions

- Make sure that the actuator is accessible from all sides to ensure convenient handwheel operation,
electrical connection, and replacement of assemblies.
- Avoid direct exposure to rain, snow and other environmental influences. Select the mounting site
accordingly.
- Exclusively mount the actuator on a rigid, non-vibrating support to avoid relative motion between
the actuator and the valve.
- When mounting the actuator close to heat sources use an insulating layer or shielding.
1)
2)
1)
2)
2)
IMB 3
IMB 6
IMB 7
2.2
2.5
45
2
Ambient temperature
1)
(-25)
- 10°C ... + 55°C
1)
(-25)
- 10°C ... + 65°C
1)
2)
IMB 8
2.2
2.2
42
20
1)
and the vent screw
Oil type
Mobil SHC 629
1)
2)
1)
2)
IMV 5
IMV 6
2.5
2.5
23
17
2)
. After having mounted the
Motorbearing
(grease)
ESSO Beacon 325
5