Custom Mode 2: Channel expander, pulsed
Description: Measures pulses that occur during 5 second interval. One pulse
per 5 seconds will drive PIN 6 (GREEN) active for XX seconds, two pulses per
5 seconds will drive PIN 7 (RED) active for XX seconds, and three pulses per 5
seconds will drive PIN 8 (BLUE) active for XX seconds. XX is definable between
.1 and 300 seconds.
Connections:
Interface wiring
Pin 2 (Purple)
Pin 3 (White)
Pin 4 (Pink)
Pin 5 (Orange)
Pin 6 (Green)
Pin 7 (Red)
Pin 8 (Blue)
Pin 9 (Brown)
Pin 10 (Gray)
To
Ground
Ground
Ground
Ground
Negative pulsed output (500 mA max) (2 pulses to activate)
Negative pulsed output (500 mA max) (1 pulse to activate)
Positive pulsed output (2 amp max) (3 pulses to activate)
Positive pulse input (use only one)