arcelik OCD 608 YI 사용자 설명서 - 페이지 12

{카테고리_이름} arcelik OCD 608 YI에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. arcelik OCD 608 YI 16 페이지.

Room ventilation
All rooms require an openable window, or
equvalent, and some rooms will require a
permanent vent as well.
The air for combustion is taken from the room air
and the exhaust gases are emitted directly into
the room.
Good room ventilation is essential for safe
operation of your appliance. If there is no window
or door available for room ventilation, an extra
ventilation must be installed.
The appliance may be located in a kitchen,
kitchen/diner or a bed-sitting room, but not in a
room containing a bath or shower. The appliance
must not be installed in a bed-sitting room of
3
less than 20m
.
Do not install this appliance in a room below
ground level unless it is open to ground level on
at least one side.
12/EN
Room size
Room size
Room size
Room size
3
smaller than 5 m
3
3
5 m
to 10 m
3
'den not required
greater than 10 m
In the cellar or
basement

Installation and connection

Product can only be installed and connected
in accordance with the statutory installation
rules.
Electrical connection
Connect the product to a grounded outlet/line
protected by a fuse of suitable capacity as stated
in the "Technical specifications" table. Have the
grounding installation made by a qualified
electrician while using the product with or
without a transformer. Our company shall not be
liable for any damages that will arise due to
using the product without a grounding installation
in accordance with the local regulations.
Ventilation opening
Ventilation opening
Ventilation opening
Ventilation opening
2
min. 100 cm
2
min. 50 cm
2
min. 65 cm