AXYS H90 설치 매뉴얼 - 페이지 8

{카테고리_이름} AXYS H90에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AXYS H90 16 페이지. Intellivox adc

MECHANICAL INSTALLATION

Acoustic Centre

Mounting an Intellivox ADC loudspeaker is a straight-
forward procedure, but it is essential to understand that the
precise mounting location is extremely critical. The correct
mounting location is defined as part of the acoustical
design process and the installer should make sure that
he/she has this information before commencing to mount
the Intellivox ADC.
MODEL V90 ONLY
The correct operational height defined by the system
designer is the height of the Intellivox ADC's acoustic
centre. This point does not necessarily coincide with the
position of any particular physical component on the
unit. The location of the speaker's acoustic centre is
marked by the centre of the yellow sticker on the front
face of the unit at the time of shipping, and it is this
position that must correspond to the operational height
defined in the design process.
The vertical position of the acoustic centre of the Model
V90 is towards the top of the unit, as indicated by the
yellow sticker (see fig.3). The horizontal position is on
the vertical centre line.
When calculating the positions for the mountings (see
below), the distance from the acoustic centre to the top
or bottom of the loudspeaker (whichever is being used as
the reference datum) should be measured and then
allowed for when marking the mounting positions. The
specification sheet supplied with each loudspeaker
includes a mechanical drawing clearly showing the
mounting position locations.
The V90 will normally be mounted perpendicular to the
listening plane, i.e. vertically when the floor is a
conventional horizontal plane. However, if the DDA
investigation has specified a downward angle for some
reason, this angle must be adhered to in the mounting
process. This is likely to necessitate the use of spacers on
the upper mounting bracket.
8
fig.3 Sticker showing acoustic centre and unit orientation
Because of the tightly-controlled vertical radiation
pattern of the V90, a small deviation from the calculated
acoustical mounting height or vertical mounting angle
may cause severe degradation of the expected
performance.
Note also that the yellow sticker indicates which way is
"up"; ensure that this orientation is observed.
fig.4.1 Acoustic centre reference point for V90
AXYS
®
Intellivox ADC Installation Manual
Reference point for
acoustical mounting
height - V90
200905/ADCIM_v1.0