c) ELECTRICAL
WARNING: THIS SHOWER MUST BE EARTHED.
The electrical installation must be in accordance with the current BS.7671 (IEE Wiring Regulations)
and "Part P" of the Building Regulations and/or local regulations.
1. The shower unit is designed for a single phase AC electrical supply.
Please check the rating plate on the unit to see what details apply to your shower.
AS A GUIDE ONLY
(* Only applies if external earth impedance is less than 0.35 Ohms)
Rating
Cable Sizes
6.0mm²
10.0mm²
8.5 / 7.8kW 240 / 230V
6.0mm²
10.0mm²
6.0mm²
10.0mm²
9.5 / 8.7kW 240 / 230V
6.0mm²
10.0mm²
10.5 / 9.6kW 240 / 230V
10.0mm²
Remember to upgrade the cable if it runs in thermal insulation in a loft, or for a longer distance.
2. A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with
the wiring rules. We recommend a ceiling switch mounted in a convenient position.
3. If you have decided to connect the cable on the left hand side then please remove and use the
cable clamp that was provided along the right side (see Diagram 3a/b).
WARNING: IF LEFT HAND SIDE CABLE ENTRY IS USED, THE MAINS CABLE OUTER SHEATH
MUST BE STRIPPED BACK TO THE LEVEL MARKED ON THE BACKPLATE, AND ALL
THREE CONDUCTORS MUST BE FULLY SLEEVED WITH THE SLEEVING PROVIDED
BETWEEN THERE AND THE TERMINAL BLOCK (SEE DIAGRAM 3a).
4. Connect cable to terminal block making sure that all the retaining screws are VERY
TIGHT and that no cable insulation is trapped under the screws.
WARNING: FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD
RESULT IN FAILURE OF THE TERMINAL BLOCK.
5. Re-fit the detachable bottom section with the two screws if it was removed.
IMPORTANT: Ensure you connect the flying lead from PCB to the front cover.
6. Re-fit the front cover, and secure by replacing the top and bottom fastening screws.
Fuse / MCB
Cable Length
27m Max.
40A Type B MCB
45m Max.
12m Max.*
45A BS.1361 fuse
21m Max.*
27m Max.
40A Type B MCB
45m Max.
12m Max.*
45A BS.1361 fuse
21m Max.*
45A BS.1361 fuse
12m Max.*
6
7. Fit the shower hose, and operate the shower first without the handset to flush out particles,
fit the handset and then operate the shower as on page 8 or 12 and check:
Water gets to a satisfactory temperature and water flow can be adjusted by control knob "E".
Knob "E" has been correctly engaged by ensuring that the knob turns approximately one full turn.
Power selection operates in all 3 button settings, giving a change in water temperature.
Check again for leaks and that the holes in the shower handset are not blocked.
8. Demonstrate the showers operation to all users.

ASSEMBLY OF ACCESSORIES

Diagram 4 (Riser Rail and Soap-Dish Fitting Instructions)
(Refer to the separate fitting instruction sheet packed with the accessories for more details)
1. Establish height of riser rail to suit user requirements.
This should be a maximum of 0.6 metres (2ft)
above the level of the heater, see (a) and Diagram 1.
2. Remove covers from the wall brackets (b).
3. Hold the rail assembly in the selected position against
the wall, ensure that the brackets are vertically aligned,
and mark the wall for upper and lower screw fixings (c).
NOTE: The adjustable slider grips the conical nut on the shower hose (e).

HOW TO MAINTAIN YOUR JETSPA SHOWER

It is recommended that the shower unit and hose etc. be cleaned using a soft cloth and that the use of
abrasive or solvent based cleaning fluid be avoided, especially on any plated finishes.
We recommend that before any cleaning, the isolating switch be turned off, thus avoiding accidentally
switching on the shower.
WARNING: YOU MUST REGULARLY INSPECT THE SHOWER HOSE FOR WEAR
AND DAMAGE. REPLACE IF NECESSARY, OR EVERY TWO YEARS,
WITH AN APPROVED PART.
WARNING: IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER,
YOU MUST REGULARLY CLEAN THE SHOWER HANDSET.
All water contains particles of lime-scale, which build up in the shower handset and
unit reducing the performance.
It is therefore important to clean the shower handset by simply rubbing the rubber
nozzles, or soaking in proprietary lime-scale remover and rinsing thoroughly before use.
NOTE: After use it is normal for some water to drip from the shower handset for a
few moments. This inhibits lime-scale build-up over prolonged use.
ADDITIONAL ACCESSORIES
Please Note:- The fitting of Spare Parts must be supervised by a suitably qualified person.
WRAS Listed Water
Isolating Valve
Cat No. 93792452
Curtain and Rail Pack
Cat No. 83792812
A more comprehensive list of additional accessories and spare parts can be supplied
against any Credit or Debit cards from Creda Sales Hotline 0870 9000 420
4. Drill and plug the wall.
5. Remove lower bracket from the rail and fit the
adjustable slider, hose-retaining ring and
soap dish onto the rail (d).
6. Replace the lower bracket and fix the
assembly to the wall.
7. Replace the covers onto both brackets.
COMMON SPARE PARTS
Front Cover without PCB
Cat No. 93590383
Front Cover complete with PCB
Cat No. 93590384
Thermal Cut-Out 50/88°C
Cat No. 93597871
Solenoid Valve
Cat No. 93590355
7