17760 ROWLAND ST.
CITY OF INDUSTRY
CALIFORNIA 91748
www.aal.net
MicroCore Upgrade Kit Installation Guide
TM
Fixture: Universe Collection Medium (UCM) (HID to LED)
2.
REMOVE EXISTING BALLAST ASSEMBLY
3.
DISASSEMBLE DOME AND HOOD
1. Remove the hood by unscrewing (4)
1/4-20 hex bolts as shown in Fig. 3-1.
2. Save the hood, dome, (4) 1/4-20 hex
bolts and (4) washers for later use. Discard
everything else.
93046644 REV. D
Tel(626)968-5666
Fax(626)968-5716
LOCKING PIN
FIG. 2-1
1. Locate locking pin on ballast
plate as shown in Fig. 2-1 & 2.1A.
2. Loosen locking pin by turning it
counter clockwise until stopped as
shown in Fig. 2-1A. Do not
disengage.
4X 1/4" WASHER
4X 1/4-20 HEX BOLTS
FIG. 3-1
PAGE 3/7
A R C H I T E C T U R A L
FIG. 2-1A
3. Turn handle counter clockwise until range
of rotation stops as shown in Fig. 2-2 and
pull existing ballast assembly out.
4. Once removed, disconnect and discard
existing ballast into E-waste.
3. Detach the dome and hood as shown in
Fig. 3-2.
A R E A
L I G H T I N G
HANDLE
FIG. 2-2