CABLE ASSEMBLY WIRING
REMOVE END COVER AND BOTTOM COVER FROM DEVICE SEE FIGURE 3.
PLACE WIRE HARNESS ON THE CARRIER WITH THE CONNECTOR AT THE HEAD OF
THE DEVICE. ALLOW 6" FOR CONNECTION TO TRIM CONTROL CONNECTOR, WHICH
HAS BEEN PULLED THROUGH ACESS HOLE IN DOOR.
SECURE CABLE IN 2 PLACES WITH SELF ADHESIVE MOUNTS AND TY-WRAPS
INCLUDED WITH CABLE ASSEMBLY. LOCATE TY-WRAPS SO THAT CABLE DOES NOT
INTERFERE WITH TRIM SLIDE OR OTHER MOVING MECHANICAL PARTS.
REPLACE END COVER AND BOTTOM COVER.
MOUNT DEVICE SO THAT TRIM TAILPIECE IS INSERTED INTO DEVICE CAM SLOT IN
HORIZONTAL POSITION AS SHOWN ABOVE IN FIGURE 1.
CONNECT CABLE CONNECTOR TO TRIM CONNECTOR AND CONTINUE MOUNTING
DEVICE ACCORDING TO MANUFACTURERS INSTRUCTIONS.
FIGURE 3
POWER TRANSFER HOOKUP DIAGRAM
¾" DIA.
WIRE
ACCESS
HOLE
4" MAXIMUM
LOCATE AND PREPARE WIRE ACCESS HOLE TO
POWER TRANSFER DEVICE AS SHOWN.
2720 CLARK AVE.
ST. LOUIS, MO 63103
(800) 753-5558